  • Accuracy: 0.36°F (0.20°C) or 0.1% of span
  • Input 2, 3, 4 wire RTDs, thermocouple, millivolt, ohm
  • Operating temp: -40 to 185°F (-40 to 85°C)
  • Input/output isolation tested to 500 Vac rms
  • DIN B style head mount or rail mount
  • Less than 0.5 seconds update time
  • 32 seconds maximum. 5 seconds default damping
  • Custom Alarm and Saturation Levels
  • HART/4-20 mA Communication Protocol
Availability:
Quantity:

Rosemount 248 Temperature Transmitter Introduction

Rosemount 248 Temperature Transmitter delivers consistent and reliable performance for process environments. Engineered to meet requirements for common single point temperature measurement applications, its durable design withstands a wide range of process environments. For application flexibility, this temperature transmitter is available in a rail or head mount configuration as well as a variety of housing options.

The Rosemount 248 Temperature Transmitter is designed to meet common Single Point measurement application requirements. This transmitter with HART protocol can easily be ordered with a variety of sensors (RTDs and thermocouples) and thermowells.

Rosemount 248 Temperature Transmitter Feature


  • Standard transmitter meets common single point temperature measurement application requirements

  • Housing construction provides superior resistance to many process environments

  • Available in rail or head mount configuration for application flexibility

  • One-year stability rating reduces maintenance costs

  • Open/short sensor diagnostics help detect issues in the sensor loop to ensure reliable performance

  • Device dashboards provide easy interface for simplified device configuration and diagnostic troubleshooting

Rosemount 248 Temperature Transmitter Specification 


    • Input

      Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)

    • Output Signal

      4-20 mA /HART® protocol

    • Housing

      DIN B head mount or rail mount

    • Diagnostics

      Basic diagnostics including open/short sensor diagnostics

    • Calibration Options

      5-point calibration

    • Certifications/Approvals

      Hazardous location, marine type, see full specs for complete list of certifications